10 CFR 431.344
§ 431.344 Test procedure for measuring and determining energy efficiency of compressors.
United States · 10 CFR — Energy · Status: effective
Cite this
- Citation
- 10 CFR 431.344, § 431.344 Test procedure for measuring and determining energy efficiency of compressors, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/39589
- Permanent ID
ys:prov:39589@1- SHA-256
5b89f964c19167df680e26fe02d6d8ad33bb7b76124bdf28a4b98fa5ddae44b1
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Scope. This section is a test procedure that is applicable to a compressor that meets the following criteria:
(1) Is an air compressor;
(2) Is a rotary compressor;
(3) Is not a liquid ring compressor;
(4) Is driven by a brushless electric motor;
(5) Is a lubricated compressor;
(6) Has a full-load operating pressure greater than or equal to 75 pounds per square inch gauge (psig) and less than or equal to 200 psig;
(7) Is not designed and tested to the requirements of the American Petroleum Institute Standard 619, “Rotary-Type Positive-Displacement Compressors for Petroleum, Petrochemical, and Natural Gas Industries;”
(8) Has full-load actual volume flow rate greater than or equal to 35 cubic feet per minute (cfm), or is distributed in commerce with a compressor motor nominal horsepower greater than or equal to 10 horsepower (hp); and
(9) Has a full-load actual volume flow rate less than or equal to 1,250 cfm, or is distributed in commerce with a compressor motor nominal horsepower less than or equal to 200 hp.
(b) Testing and calculations. Determine the applicable full-load package isentropic efficiency (ηisen,FL), part-load package isentropic efficiency (ηisen,PL), package specific power, maximum full-flow operating pressure, full-load operating pressure, full-load actual volume flow rate, and pressure ratio at full-load operating pressure using the test procedure set forth in appendix A of this subpart.
Legislative history