yourstate.us
10 CFR 431.345

§ 431.345 Energy conservation standards and effective dates.

United States · 10 CFR — Energy · Status: effective

Get this as JSONEmbed this
Cite this
Citation
10 CFR 431.345, § 431.345 Energy conservation standards and effective dates, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/39590
Permanent ID
ys:prov:39590@1
SHA-256
84492cafdd9c640ef8ecc62515befd8a3dbd6f166f2b6e3ad5e2c3d0393d622b

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Each compressor that is manufactured starting on January 10, 2025 and that: (1) Is an air compressor, (2) Is a rotary compressor, (3) Is not a liquid ring compressor, (4) Is driven by a brushless electric motor, (5) Is a lubricated compressor, (6) Has a full-load operating pressure greater than or equal to 75 pounds per square inch gauge (psig) and less than or equal to 200 psig, (7) Is not designed and tested to the requirements of The American Petroleum Institute standard 619, “Rotary-Type Positive-Displacement Compressors for Petroleum, Petrochemical, and Natural Gas Industries,” (8) Has full-load actual volume flow rate greater than or equal to 35 cubic feet per minute (cfm), or is distributed in commerce with a compressor motor nominal horsepower greater than or equal to 10 horsepower (hp), (9) Has a full-load actual volume flow rate less than or equal to 1,250 cfm, or is distributed in commerce with a compressor motor nominal horsepower less than or equal to 200 hp, (10) Is driven by a three-phase electric motor, (11) Is manufactured alone or as a component of another piece of equipment; and (12) Is in one of the equipment classes listed in the Table 1, must have a full-load package isentropic efficiency or part-load package isentropic efficiency that is not less than the appropriate “Minimum Package Isentropic Efficiency” value listed in Table 1 of this section. Table 1—Energy Conservation Standards for Certain Compressors (b) Instructions for the use of Table 1 of this section: (1) To determine the standard level a compressor must meet, the correct equipment class must be identified. The descriptions are in the first column (“Equipment Class”); definitions for these descriptions are found in § 431.342. (2) The second column (“Minimum Package Isentropic Efficiency”) contains the applicable energy conservation standard level, provided in terms of package isentropic efficiency. (3) For “Fixed-speed compressor” equipment classes, the relevant Package Isentropic Efficiency is Full-load Package Isentropic Efficiency. For “Variable-speed compressor” equipment classes, the relevant Package Isentropic Efficiency is Part-load Package Isentropic Efficiency. Both Full- and Part-load Package Isentropic Efficiency are determined in accordance with the test procedure in § 431.344. (4) The second column (“Minimum Package Isentropic Efficiency”) references the third column (“ηRegr”), also a function of full-load actual volume flow rate, and the fourth column (“d”). The equations are provided separately to maintain consistency with the language of the preamble and analysis. (5) The second and third columns contain the term V1, which denotes compressor full-load actual volume flow rate, given in terms of cubic feet per minute (“cfm”) and determined in accordance with the test procedure in § 431.344.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.