14 CFR 25.365
§ 25.365 Pressurized compartment loads.
United States · 14 CFR — Aeronautics and Space · Status: effective
Cite this
- Citation
- 14 CFR 25.365, § 25.365 Pressurized compartment loads, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/54028
- Permanent ID
ys:prov:54028@1- SHA-256
b790f91cb9a34c53c8e1709475ff3393c8a6d818910debfec5dc2a80d1014b84
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
For airplanes with one or more pressurized compartments the following apply:
(a) The airplane structure must be strong enough to withstand the flight loads combined with pressure differential loads from zero up to the maximum relief valve setting.
(b) The external pressure distribution in flight, and stress concentrations and fatigue effects must be accounted for.
(c) If landings may be made with the compartment pressurized, landing loads must be combined with pressure differential loads from zero up to the maximum allowed during landing.
(d) The airplane structure must be designed to be able to withstand the pressure differential loads corresponding to the maximum relief valve setting multiplied by a factor of 1.33 for airplanes to be approved for operation to 45,000 feet or by a factor of 1.67 for airplanes to be approved for operation above 45,000 feet, omitting other loads.
(e) Any structure, component or part, inside or outside a pressurized compartment, the failure of which could interfere with continued safe flight and landing, must be designed to withstand the effects of a sudden release of pressure through an opening in any compartment at any operating altitude resulting from each of the following conditions:
(1) The penetration of the compartment by a portion of an engine following an engine disintegration;
(2) Any opening in any pressurized compartment up to the size Ho in square feet; however, small compartments may be combined with an adjacent pressurized compartment and both considered as a single compartment for openings that cannot reasonably be expected to be confined to the small compartment. The size Ho must be computed by the following formula:
where,
(3) The maximum opening caused by airplane or equipment failures not shown to be extremely improbable.
(f) In complying with paragraph (e) of this section, the fail-safe features of the design may be considered in determining the probability of failure or penetration and probable size of openings, provided that possible improper operation of closure devices and inadvertent door openings are also considered. Furthermore, the resulting differential pressure loads must be combined in a rational and conservative manner with 1-g level flight loads and any loads arising from emergency depressurization conditions. These loads may be considered as ultimate conditions; however, any deformations associated with these conditions must not interfere with continued safe flight and landing. The pressure relief provided by intercompartment venting may also be considered.
(g)(1) Except as provided in paragraph (g)(2) of this section, bulkheads, floors, and partitions in pressurized compartments for occupants must be designed to withstand the conditions specified in paragraph (e) of this section. In addition, reasonable design precautions must be taken to minimize the probability of parts becoming detached and injuring occupants while in their seats.
(2) Partitions adjacent to the opening specified in paragraph (e)(2) of this section need not be designed to withstand that condition provided—
(i) Failure of the partition would not interfere with continued safe flight and landing; and
(ii) Designing the partition to withstand the condition specified in paragraph (e)(2) of this section would be impractical.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.