§ 25.393 Loads parallel to hinge line.

United States · 14 CFR — Aeronautics and Space · Status: effective

Get this as JSONEmbed this
Cite this
Citation
14 CFR 25.393, § 25.393 Loads parallel to hinge line, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/54033
Permanent ID
ys:prov:54033@1
SHA-256
dacc9f509ce31ebe981d23f2f5a2160370ea9f4274e3bc787d42057041aac0cf

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Control surfaces and supporting hinge brackets must be designed for inertia loads acting parallel to the hinge line. (b) In the absence of more rational data, the inertia loads may be assumed to be equal to KW, where— (1) K = 24 for vertical surfaces; (2) K = 12 for horizontal surfaces; and (3) W = weight of the movable surfaces.