14 CFR 25.689
§ 25.689 Cable systems.
United States · 14 CFR — Aeronautics and Space · Status: effective
Cite this
- Citation
- 14 CFR 25.689, § 25.689 Cable systems, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/54103
- Permanent ID
ys:prov:54103@1- SHA-256
32ed480e8987f22845c02c31322ca7f8b272c7b4079cdae85b49d5da4f2ef8cd
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Each cable, cable fitting, turnbuckle, splice, and pulley must be approved. In addition—
(1) No cable smaller than 1/8 inch in diameter may be used in the aileron, elevator, or rudder systems; and
(2) Each cable system must be designed so that there will be no hazardous change in cable tension throughout the range of travel under operating conditions and temperature variations.
(b) Each kind and size of pulley must correspond to the cable with which it is used. Pulleys and sprockets must have closely fitted guards to prevent the cables and chains from being displaced or fouled. Each pulley must lie in the plane passing through the cable so that the cable does not rub against the pulley flange.
(c) Fairleads must be installed so that they do not cause a change in cable direction of more than three degrees.
(d) Clevis pins subject to load or motion and retained only by cotter pins may not be used in the control system.
(e) Turnbuckles must be attached to parts having angular motion in a manner that will positively prevent binding throughout the range of travel.
(f) There must be provisions for visual inspection of fairleads, pulleys, terminals, and turnbuckles.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.