14 CFR 25.945
§ 25.945 Thrust or power augmentation system.
United States · 14 CFR — Aeronautics and Space · Status: effective
Cite this
- Citation
- 14 CFR 25.945, § 25.945 Thrust or power augmentation system, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/54180
- Permanent ID
ys:prov:54180@1- SHA-256
91c340924dbb0609c7fda5c411e4a7a4735b9e89189444a5826490a7f77a2068
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) General. Each fluid injection system must provide a flow of fluid at the rate and pressure established for proper engine functioning under each intended operating condition. If the fluid can freeze, fluid freezing may not damage the airplane or adversely affect airplane performance.
(b) Fluid tanks. Each augmentation system fluid tank must meet the following requirements:
(1) Each tank must be able to withstand without failure the vibration, inertia, fluid, and structural loads that it may be subject to in operation.
(2) The tanks as mounted in the airplane must be able to withstand without failure or leakage an internal pressure 1.5 times the maximum operating pressure.
(3) If a vent is provided, the venting must be effective under all normal flight conditions.
(4) [Reserved]
(5) Each tank must have an expansion space of not less than 2 percent of the tank capacity. It must be impossible to fill the expansion space inadvertently with the airplane in the normal ground attitude.
(c) Augmentation system drains must be designed and located in accordance with § 25.1455 if—
(1) The augmentation system fluid is subject to freezing; and
(2) The fluid may be drained in flight or during ground operation.
(d) The augmentation liquid tank capacity available for the use of each engine must be large enough to allow operation of the airplane under the approved procedures for the use of liquid-augmented power. The computation of liquid consumption must be based on the maximum approved rate appropriate for the desired engine output and must include the effect of temperature on engine performance as well as any other factors that might vary the amount of liquid required.
(e) This section does not apply to fuel injection systems.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.