14 CFR 25.951

§ 25.951 General.

United States · 14 CFR — Aeronautics and Space · Status: effective

Get this as JSONEmbed this
Cite this
Citation
14 CFR 25.951, § 25.951 General, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/54181
Permanent ID
ys:prov:54181@1
SHA-256
6a3603fe83bc03b89c7ca42697d18dd2c678b090ad0409c94ec889c4b8616b14

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Each fuel system must be constructed and arranged to ensure a flow of fuel at a rate and pressure established for proper engine and auxiliary power unit functioning under each likely operating condition, including any maneuver for which certification is requested and during which the engine or auxiliary power unit is permitted to be in operation. (b) Each fuel system must be arranged so that any air which is introduced into the system will not result in— (1) Power interruption for more than 20 seconds for reciprocating engines; or (2) Flameout for turbine engines. (c) Each fuel system for a turbine engine must be capable of sustained operation throughout its flow and pressure range with fuel initially saturated with water at 80 °F and having 0.75cc of free water per gallon added and cooled to the most critical condition for icing likely to be encountered in operation. (d) Each fuel system for a turbine engine powered airplane must meet the applicable fuel venting requirements of part 34 of this chapter.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.