§ 25.1187 Drainage and ventilation of fire zones.

United States · 14 CFR — Aeronautics and Space · Status: effective

Get this as JSONEmbed this
Cite this
Citation
14 CFR 25.1187, § 25.1187 Drainage and ventilation of fire zones, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/54246
Permanent ID
ys:prov:54246@1
SHA-256
768e402c72067b558d6272c85e8a24565c194c17e6c65648f132935125644344

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) There must be complete drainage of each part of each designated fire zone to minimize the hazards resulting from failure or malfunctioning of any component containing flammable fluids. The drainage means must be— (1) Effective under conditions expected to prevail when drainage is needed; and (2) Arranged so that no discharged fluid will cause an additional fire hazard. (b) Each designated fire zone must be ventilated to prevent the accumulation of flammable vapors. (c) No ventilation opening may be where it would allow the entry of flammable fluids, vapors, or flame from other zones. (d) Each ventilation means must be arranged so that no discharged vapors will cause an additional fire hazard. (e) Unless the extinguishing agent capacity and rate of discharge are based on maximum air flow through a zone, there must be means to allow the crew to shut off sources of forced ventilation to any fire zone except the engine power section of the nacelle and the combustion heater ventilating air ducts.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.