14 CFR 25.1189
§ 25.1189 Shutoff means.
United States · 14 CFR — Aeronautics and Space · Status: effective
Cite this
- Citation
- 14 CFR 25.1189, § 25.1189 Shutoff means, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/54247
- Permanent ID
ys:prov:54247@1- SHA-256
8b0d39af0b4e89edd824d41d1e9cd890493a24d9d959265e50477fbed5388755
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Each engine installation and each fire zone specified in § 25.1181(a)(4) and (5) must have a means to shut off or otherwise prevent hazardous quantities of fuel, oil, deicer, and other flammable fluids, from flowing into, within, or through any designated fire zone, except that shutoff means are not required for—
(1) Lines, fittings, and components forming an integral part of an engine; and
(2) Oil systems for turbine engine installations in which all components of the system in a designated fire zone, including oil tanks, are fireproof or located in areas not subject to engine fire conditions.
(b) The closing of any fuel shutoff valve for any engine may not make fuel unavailable to the remaining engines.
(c) Operation of any shutoff may not interfere with the later emergency operation of other equipment, such as the means for feathering the propeller.
(d) Each flammable fluid shutoff means and control must be fireproof or must be located and protected so that any fire in a fire zone will not affect its operation.
(e) No hazardous quantity of flammable fluid may drain into any designated fire zone after shutoff.
(f) There must be means to guard against inadvertent operation of the shutoff means and to make it possible for the crew to reopen the shutoff means in flight after it has been closed.
(g) Each tank-to-engine shutoff valve must be located so that the operation of the valve will not be affected by powerplant or engine mount structural failure.
(h) Each shutoff valve must have a means to relieve excessive pressure accumulation unless a means for pressure relief is otherwise provided in the system.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.