14 CFR 27.1435
§ 27.1435 Hydraulic systems.
United States · 14 CFR — Aeronautics and Space · Status: effective
Cite this
- Citation
- 14 CFR 27.1435, § 27.1435 Hydraulic systems, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/54639
- Permanent ID
ys:prov:54639@1- SHA-256
4ce76c03db94359f21e235c96cd2e61a593a6d55940d21dc5086dd9818d94939
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Design. Each hydraulic system and its elements must withstand, without yielding, any structural loads expected in addition to hydraulic loads.
(b) Tests. Each system must be substantiated by proof pressure tests. When proof tested, no part of any system may fail, malfunction, or experience a permanent set. The proof load of each system must be at least 1.5 times the maximum operating pressure of that system.
(c) Accumulators. No hydraulic accumulator or pressurized reservoir may be installed on the engine side of any firewall unless it is an integral part of an engine.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.