yourstate.us
14 CFR 29.861

§ 29.861 Fire protection of structure, controls, and other parts.

United States · 14 CFR — Aeronautics and Space · Status: effective

Get this as JSONEmbed this
Cite this
Citation
14 CFR 29.861, § 29.861 Fire protection of structure, controls, and other parts, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/54829
Permanent ID
ys:prov:54829@1
SHA-256
5e5469f4f0ca05d3cf3cc6bcc0876f1ad128dae2b0fc93b7c88c6e9d664f84d9

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

Each part of the structure, controls, and the rotor mechanism, and other parts essential to controlled landing and (for category A) flight that would be affected by powerplant fires must be isolated under § 29.1191, or must be— (a) For category A rotorcraft, fireproof; and (b) For Category B rotorcraft, fireproof or protected so that they can perform their essential functions for at least 5 minutes under any foreseeable powerplant fire conditions.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.