14 CFR 29.1013

§ 29.1013 Oil tanks.

United States · 14 CFR — Aeronautics and Space · Status: effective

Get this as JSONEmbed this
Cite this
Citation
14 CFR 29.1013, § 29.1013 Oil tanks, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/54870
Permanent ID
ys:prov:54870@1
SHA-256
ff646e9685d9b5260bb326086f3503605378281034e5581cdf61fdf0ff3d7293

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Installation. Each oil tank installation must meet the requirements of § 29.967. (b) Expansion space. Oil tank expansion space must be provided so that— (1) Each oil tank used with a reciprocating engine has an expansion space of not less than the greater of 10 percent of the tank capacity or 0.5 gallon, and each oil tank used with a turbine engine has an expansion space of not less than 10 percent of the tank capacity; (2) Each reserve oil tank not directly connected to any engine has an expansion space of not less than two percent of the tank capacity; and (3) It is impossible to fill the expansion space inadvertently with the rotorcraft in the normal ground attitude. (c) Filler connections. Each recessed oil tank filler connection that can retain any appreciable quantity of oil must have a drain that discharges clear of the entire rotorcraft. In addition— (1) Each oil tank filler cap must provide an oil-tight seal under the pressure expected in operation; (2) For category A rotorcraft, each oil tank filler cap or filler cap cover must incorporate features that provide a warning when caps are not fully locked or seated on the filler connection; and (3) Each oil filler must be marked under § 29.1557(c)(2). (d) Vent. Oil tanks must be vented as follows: (1) Each oil tank must be vented from the top part of the expansion space to that venting is effective under all normal flight conditions. (2) Oil tank vents must be arranged so that condensed water vapor that might freeze and obstruct the line cannot accumulate at any point; (e) Outlet. There must be means to prevent entrance into the tank itself, or into the tank outlet, of any object that might obstruct the flow of oil through the system. No oil tank outlet may be enclosed by a screen or guard that would reduce the flow of oil below a safe value at any operating temperature. There must be a shutoff valve at the outlet of each oil tank used with a turbine engine unless the external portion of the oil system (including oil tank supports) is fireproof. (f) Flexible liners. Each flexible oil tank liner must be approved or shown to be suitable for the particular installation.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.