yourstate.us
14 CFR 29.1181

§ 29.1181 Designated fire zones: regions included.

United States · 14 CFR — Aeronautics and Space · Status: effective

Get this as JSONEmbed this
Cite this
Citation
14 CFR 29.1181, § 29.1181 Designated fire zones: regions included, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/54903
Permanent ID
ys:prov:54903@1
SHA-256
4b3605552a23932a267304754925d716b5fd49094964a9c8cc937e17c18c5506

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Designated fire zones are— (1) The engine power section of reciprocating engines; (2) The engine accessory section of reciprocating engines; (3) Any complete powerplant compartment in which there is no isolation between the engine power section and the engine accessory section, for reciprocating engines; (4) Any auxiliary power unit compartment; (5) Any fuel-burning heater and other combustion equipment installation described in § 29.859; (6) The compressor and accessory sections of turbine engines; and (7) The combustor, turbine, and tailpipe sections of turbine engine installations except sections that do not contain lines and components carrying flammable fluids or gases and are isolated from the designated fire zone prescribed in paragraph (a)(6) of this section by a firewall that meets § 29.1191. (b) Each designated fire zone must meet the requirements of §§ 29.1183 through 29.1203.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.