yourstate.us
14 CFR 29.1193

§ 29.1193 Cowling and engine compartment covering.

United States · 14 CFR — Aeronautics and Space · Status: effective

Get this as JSONEmbed this
Cite this
Citation
14 CFR 29.1193, § 29.1193 Cowling and engine compartment covering, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/54909
Permanent ID
ys:prov:54909@1
SHA-256
b823149784c32e79600aa99fc7f89aefc3bb9fb8bef4a7ad1a1765bd4552c024

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Each cowling and engine compartment covering must be constructed and supported so that it can resist the vibration, inertia, and air loads to which it may be subjected in operation. (b) Cowling must meet the drainage and ventilation requirements of § 29.1187. (c) On rotorcraft with a diaphragm isolating the engine power section from the engine accessory section, each part of the accessory section cowling subject to flame in case of fire in the engine power section of the powerplant must— (1) Be fireproof; and (2) Meet the requirements of § 29.1191. (d) Each part of the cowling or engine compartment covering subject to high temperatures due to its nearness to exhaust system parts or exhaust gas impingement must be fireproof. (e) Each rotorcraft must— (1) Be designated and constructed so that no fire originating in any fire zone can enter, either through openings or by burning through external skin, any other zone or region where it would create additional hazards; (2) Meet the requirements of paragraph (e)(1) of this section with the landing gear retracted (if applicable); and (3) Have fireproof skin in areas subject to flame if a fire starts in or burns out of any designated fire zone. (f) A means of retention for each openable or readily removable panel, cowling, or engine or rotor drive system covering must be provided to preclude hazardous damage to rotors or critical control components in the event of— (1) Structural or mechanical failure of the normal retention means, unless such failure is extremely improbable; or (2) Fire in a fire zone, if such fire could adversely affect the normal means of retention.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.