yourstate.us
14 CFR 33.92

§ 33.92 Rotor locking tests.

United States · 14 CFR — Aeronautics and Space · Status: effective

Get this as JSONEmbed this
Cite this
Citation
14 CFR 33.92, § 33.92 Rotor locking tests, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/55108
Permanent ID
ys:prov:55108@1
SHA-256
160289f6501ef6f433835f3b62c91019285d3fd95f76db78ebc6dad08d43d3e4

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

If continued rotation is prevented by a means to lock the rotor(s), the engine must be subjected to a test that includes 25 operations of this means under the following conditions: (a) The engine must be shut down from rated maximum continuous thrust or power; and (b) The means for stopping and locking the rotor(s) must be operated as specified in the engine operating instructions while being subjected to the maximum torque that could result from continued flight in this condition; and (c) Following rotor locking, the rotor(s) must be held stationary under these conditions for five minutes for each of the 25 operations.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.