yourstate.us
16 CFR 1203.14

§ 1203.14 Peripheral vision test.

United States · 16 CFR — Commercial Practices · Status: effective

Get this as JSONEmbed this
Cite this
Citation
16 CFR 1203.14, § 1203.14 Peripheral vision test, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/65470
Permanent ID
ys:prov:65470@1
SHA-256
ec473d379719656ff0eaaf2aa8f619a3bc1b1d5f65fe59c1b1d8a63ec7f2b6e6

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

Position the helmet on a reference headform in accordance with the HPI and place a 5-kg (11-lb) preload ballast on top of the helmet to set the comfort or fit padding. (Note: Peripheral vision clearance may be determined when the helmet is positioned for marking the test lines.) Peripheral vision is measured horizontally from each side of the midsagittal plane around the point K (see Figure 6 of this part). Point K is located on the front surface of the reference headform at the intersection of the basic and midsagittal planes. The vision shall not be obstructed within 105 degrees from point K on each side of the midsagittal plane.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.