16 CFR 1500.45
§ 1500.45 Method for determining extremely flammable and flammable contents of self-pressurized containers.
United States · 16 CFR — Commercial Practices · Status: effective
Cite this
- Citation
- 16 CFR 1500.45, § 1500.45 Method for determining extremely flammable and flammable contents of self-pressurized containers, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/65934
- Permanent ID
ys:prov:65934@1- SHA-256
ff7c40d5738a3fba8abdcdcd587bb293a753e33d9131b5bf862e93a95952c07d
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Equipment required. The test equipment consists of a base 8 inches wide, 2 feet long, marked in 6-inch intervals. A rule 2 feet long and marked in inches is supported horizontally on the side of the base and about 6 inches above it. A paraffin candle 1 inch or more in diameter, and of such height that the top third of the flame is at the height of the horizontal rule, is placed at the zero point in the base.
(b) Procedure. The test is conducted in a draft-free area that can be ventilated and cleared after each test. Place the self-pressurized container at a distance of 6 inches from the flame source. Spray for periods of 15 seconds to 20 seconds (one observer noting the extension of the flame and the other operating the container) through the top third of the flame and at a right angle to the flame. The height of the flame should be approximately 2 inches. Take three readings for each test, and average. As a precaution do not spray large quantities in a small, confined space. Free space of previously discharged material.