yourstate.us
16 CFR 1507.3

§ 1507.3 Fuses.

United States · 16 CFR — Commercial Practices · Status: effective

Get this as JSONEmbed this
Cite this
Citation
16 CFR 1507.3, § 1507.3 Fuses, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/66056
Permanent ID
ys:prov:66056@1
SHA-256
9a3ae6d2a6efbe56a88af8780c40003efd898d5121d2fdbaf0bbcc8ce02a9222

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Fireworks devices that require a fuse shall: (1) Utilize only a fuse that has been treated or coated in such manner as to reduce the possibility of side ignition. Devices such as ground spinners that require a restricted orifice for proper thrust and contain less than 6 grams of pyrotechnic composition are exempted from § 1507.3(a)(1). (2) Utilize only a fuse which will burn at least 3 seconds but not more than 9 seconds before ignition of the device. (b) The fuse shall be securely attached so that it will support either the weight of the fireworks device plus 8 ounces of dead weight or double the weight of the device, whether is less, without separation from the fireworks device.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.