16 CFR 1615.3
§ 1615.3 General requirements.
United States · 16 CFR — Commercial Practices · Status: effective
Cite this
- Citation
- 16 CFR 1615.3, § 1615.3 General requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/66209
- Permanent ID
ys:prov:66209@1- SHA-256
c628d4e4d62d0299f68b19deb8c7f571741f3d273b6b826bd2e14c778ec09b47
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Summary of test method. Five conditioned specimens, 8.9 × 25.4 cm. (3.5 × 10 in.), are suspended one at a time vertically in holders in a prescribed cabinet and subjected to a standard flame along their bottom edge for a specified time under controlled conditions. The char length is measured.
(b) Test criteria. The test criteria when the testing is done in accordance with § 1615.4 Test procedure are:
(1) Average char length. The average char length of five specimens shall not exceed 17.8 cm. (7.0 in.).
(2) Full specimen burn. No individual specimen shall have a char length of 25.4 cm. (10 in.).
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.