yourstate.us
21 CFR 640.64

§ 640.64 Collection of blood for Source Plasma.

United States · 21 CFR — Food and Drugs · Status: effective

Get this as JSONEmbed this
Cite this
Citation
21 CFR 640.64, § 640.64 Collection of blood for Source Plasma, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/88500
Permanent ID
ys:prov:88500@1
SHA-256
7e21a9848e5ac436873ac853c7701dde513a2e01e232fdd07f3c441b9197ad07

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) [Reserved] (b) Blood containers. Blood containers and donor sets must be pyrogen-free, sterile, and identified by lot number. (c) The anticoagulant solution. The anticoagulant solution must be sterile and pyrogen-free. Anticoagulant solutions must be compounded and used according to a formula that has been approved for the applicant by the Director, Center for Biologics Evaluation and Research. (d) Donor identification. Each unit of blood and plasma shall be so marked or identified by number or other symbol so as to relate it directly to the donor. (e) Prevention of contamination of the blood and plasma. The skin of the donor at the site of phlebotomy shall be prepared thoroughly and carefully by a method that gives maximum assurance of a sterile container of blood. The blood shall be collected, the plasma separated, and the cells returned to the donor by aseptic methods in a sterile system which may be closed, or may be vented if the vent protects the blood cells and plasma against contamination.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.