yourstate.us
21 CFR 660.25

§ 660.25 Potency tests without reference preparations.

United States · 21 CFR — Food and Drugs · Status: effective

Get this as JSONEmbed this
Cite this
Citation
21 CFR 660.25, § 660.25 Potency tests without reference preparations, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/88548
Permanent ID
ys:prov:88548@1
SHA-256
a2ab4e5cd1a417a8e998e98075d0eb0532ace9d74658a65f9d0ccf80c60049c9

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

Products for which Reference Blood Grouping Reagents are not available shall be tested for potency by a method approved by the Director, Center for Biologics Evaluation and Research. (a) Potency requirements. Blood Grouping Reagents recommended for the test tube methods, including the indirect antiglobulin tests, shall have the following potency titer values, unless other values are approved by the Director, Center for Biologics Evaluation and Research. (1) For Anti-K, Anti-k , Anti-Jk a, Anti-Fy a, Anti-C w, at least 1 + reaction with a 1:8 dilution of the reagent. (2) For Anti-S, Anti-s , Anti-P1, Anti-M, Anti-I, Anti-e (saline), Anti-c (saline), and Anti-A1, at least 1 + reaction with a 1:4 dilution of the reagent. (3) For Anti-U, Anti-Kp a, Anti-Kp b, Anti-Js a, Anti-Js b, Anti-Fy b, Anti-N, Anti-Le a, Anti-Le b, Anti-Lu a, Anti-Lu b, Anti-Di a, Anti-M g, Anti-Jk b, Anti-Co b, Anti-Wr a, and Anti-Xg a, at least 2 + reaction with undiluted reagent. (b) Products recommended for slide tests or microplate techniques. Blood Grouping Reagent recommended for slide test methods or microplate techniques shall produce clearly positive macroscopic results when both undiluted reagent and reagent diluted with an equal volume of diluent are tested by all methods recommended in the manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the corresponding antigen. The dilution shall be made with an equal volume of compatible serum or approved diluent. (c) Products recomended for use in an automated system. The manufacturer of Blood Grouping Reagent that is recommended for use in an automated system shall demonstrate that its product when used both undiluted and diluted with an equal volume of diluent satisfactorily performs when tested with cells representing heterozygous or diminished expression of the corresponding antigen.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.