23 CFR — Highways

Appendix to Subpart F of Part 655—Alternate Method of Determining the Color of Retroreflective Sign Materials and Pavement Marking Materials

United States · 23 CFR — Highways · Status: effective

Get this as JSONEmbed this
Cite this
Citation
23 CFR — Highways, Appendix to Subpart F of Part 655—Alternate Method of Determining the Color of Retroreflective Sign Materials and Pavement Marking Materials, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/97089
Permanent ID
ys:prov:97089@1
SHA-256
99288e30d8a237e7c3ed61bc2555dcd4cbed02a94b4500b71adb347629a85739

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

1. Although the FHWA Color Tolerance Charts depreciate the use of spectrophotometers or accurate tristimulus colorimeters for measuring the daytime color of retroreflective materials, recent testing has determined that 0/45 or 45/0 spectroradiometers and tristimulus colorimeters have proved that the measurements can be considered reliable and may be used. 2. The daytime color of non-fluorescent retroreflective materials may be measured in accordance with ASTM Test Method E1349, “Standard Test Method for Reflectance Factor and Color by Spectrophotometry Using Bidirectional Geometry” or ASTM Test Method E 1347 (Replaces E97), “Standard Test Method for Color and Color-Difference Measurement by Tristimulus (Filter) Colorimetry.” The latter test method specified bidirectional geometry for the measurement of retroreflective materials. The geometric conditions to be used in both test methods are 0/45 or 45/0 circumferential illumination or viewing. Uniplanar geometry is not recommended for material types IV or higher (designated microprismatic). The CIE standard illuminant used in computing the colorimetric coordinates shall be D65 and the 2 Degree Standard CIE observer shall be used. 3. For fluorescent retroreflective materials ASTM E991 may be used to determine the chromaticity provided that the D65 illumination meets the requirements of E 991. This practice, however, allows only the total luminous factor to be measured. The fluorescent luminous factor must be determined using bispectral fluorescent colorimetry. Commercial instruments are available which allow such determination. Some testing laboratories are also equipped to perform these measurements. 4. For nighttime measurements CIE Standard Illuminant A shall be used in computing the colorimetric coordinates and the 2 Degree Standard CIE Observer shall be used. 5. Average performance sheeting is identified as Types I and II sheeting and high performance sheeting is identified as Type III. Super-high intensity sheeting is identified as Types V, VI, and VII in ASTM D 4956. 6. The following ten tables depict the 1931 CIE Chromaticity Diagram x and y coordinates for the corner points defining the recommended color boxes in the diagram and the daytime luminance factors for those colors. Lines drawn between these corner points specify the limits of the chromaticity allowed in the 1931 Chromaticity Diagram. Color coordinates of samples that lie within these lines are acceptable. For blue and green colors the spectrum locus is the defining limit between the corner points located on the spectrum locus: Table 1 to Appendix to Part 655, Subpart F—Daytime Color Specification Limits for Retroreflective Material With CIE 2° Standard Observer and 45/0 (0/45) Geometry and CIE Standard Illuminant D65. Table 1a to Appendix to Part 655, Subpart F—Daytime Luminance Factors (%) for Retroreflective Material With CIE 2° Standard Observer and 45/0 (0/45) Geometry and CIE Standard Illuminant D65. Table 2 to Appendix to Part 655, Subpart F—Nighttime Color Specification Limits for Retroreflective Material With CIE 2° Standard Observer and Observation Angle of 0.33°, Entrance Angle of + 5° and CIE Standard Illuminant A. Table 3 to Appendix to Part 655, Subpart F—Daytime Color Specification Limits for Fluorescent Retroreflective Material with CIE 2° Standard Observer and 45/0 (0/45) Geometry and CIE Standard Illuminant D65. Table 3a to Appendix to Part 655, Subpart F—Daytime Luminance Factors (%) for Fluorescent Retroreflective Material With CIE 2° Standard Observer and 45/0 (0/45) Geometry and CIE Standard Illuminant D65. Table 4 to Appendix to Part 655, Subpart F—Nighttime Color Specification Limits for Fluorescent Retroreflective Material With CIE 2° Standard Observer and Observation Angle of 0.33°, Entrance Angle of + 5° and CIE Standard Illuminant A. Table 5 to Appendix to Part 655, Subpart F—Daytime Color Specification Limits for Retroreflective Pavement Marking Material With CIE 2° Standard Observer and 45/0 (0/45) Geometry and CIE Standard Illuminant D65. Table 5a to Appendix to Part 655, Subpart F—Daytime Luminance Factors (%) for Retroreflective Pavement Marking Material With CIE 2° Standard Observer and 45/0 (0/45) Geometry and CIE Standard Illuminant D65. Table 6 to Appendix to Part 655, Subpart F—Nightime Color Specification Limits for Retroreflective Pavement Marking Material With CIE 2° Standard Observer, Observation Angle of 1.05°, Entrance Angle of + 88.76° and CIE Standard Illuminant A. Table 7 to Appendix to Part 655, Subpart F—Daytime Color Specification Limits for Non-Retroreflective Materials Used for Colored Pavements

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.