24 CFR 51.205
§ 51.205 Mitigating measures.
United States · 24 CFR — Housing and Urban Development · Status: effective
Cite this
- Citation
- 24 CFR 51.205, § 51.205 Mitigating measures, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/98456
- Permanent ID
ys:prov:98456@1- SHA-256
353ede25d52976a083e048c2a337ceead19defdc2eff176845541dc3482f279b
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
Application of the standards for determining an Acceptable Separation Distance (ASD) for a HUD-assisted project from a potential hazard of an explosion or fire prone nature is predicated on level topography with no intervening object(s) between the hazard and the project. Application of the standards can be eliminated or modified if:
(a) The nature of the topography shields the proposed project from the hazard.
(b) An existing permanent fire resistant structure of adequate size and strength will shield the proposed project from the hazard.
(c) A barrier is constructed surrounding the hazard, at the site of the project, or in between the potential hazard and the proposed project.
(d) The structure and outdoor areas used by people are designed to withstand blast overpressure and thermal radiation anticipated from the potential hazard (e.g., the project is of masonry and steel or reinforced concrete and steel construction).
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.